Products Refrigeration Products11 In-Row precision cooling33
i-Row Series variable frequency cooling

Basic Features

Modular data center efficient cooling system solution

● High thermal density areas in data centers

● Container data center

● Improve EER of refrigeration system

● Fcooling configuration combined with natural cooling source

● Modular data centers

● Reduce the overall PUE of the computer room

● Matching cold and hot channel design

?

i-Row series cooling

1.jpg

?

i-Row is an adaptive precision cooling system close to the heat source, ideal for rack level cooling in data centers

image.png

Cold and hot channel applications

image.png


Modular, container data center applications

image.png


Air supply method

Configuration 1

The unit size is 300/600 (width) x 1200 (depth) x 2000 (height)

2.jpg

Configuration 2

The unit size is 300/600 (width) x 1200 (depth) x 2000 (height)

3.jpg

Characteristics of i-Row

EVO control system

● Visualization display function, including operating status and temperature and humidity of the incoming and outgoing air of the tested cabinet

●Advanced group control function, with over 30 units and the ability to connect no less than 6000 temperature sensors externally

●Standard configuration of SNMP and TCP/IP interfaces

●DC variable frequency EC compressor

●DC variable frequency EC compressor using R410A environmentally friendly refrigeration

●Dynamic cooling to adapt to rapidly changing machine room loads

●Save energy and improve energy efficiency at low loads

●Can greatly reduce the number of compressor starts and stops, improve system reliability

image.png?

EC fan?

●Adopting electronic commutation synchronous EC motor, saving energy by 20-30%

●Soft start function, low starting current

●Automatically adjust the fan speed according to refrigeration demand or air pressure, and provide air volume as needed

●Redundant configuration of fan N+1 ensures full airflow operation even if any fan malfunctions

● Easy to maintain design

image.png

Electronic expansion valve

●Smooth adjustment of throttle opening, combined with variable capacity compressors to achieve energy-saving

●Wide adjustment range, reducing overheating, and improving energy efficiency ratio

●Achieve precise matching of cooling capacity and load?

●Fast response speed, achieving precise cooling

image.png

Optional accessories

● Dual power input switching switch

● Wireless temperature and humidity sensors

● Air supply deflector device

● Wired temperature and humidity sensors

● Low temperature starting device

● Chilled water three-way water valve

● GPRS SMS alarm

image.png

How i-Row Achieves High Energy Efficiency

●Close to the heat source, the return air temperature and evaporation pressure are improved, and the refrigeration efficiency is improved

●The system design of the unit adopts computer-aided fluid dynamics (CFD) calculations to ensure the optimal distribution of airflow within the unit and between racks

●DC variable frequency EC compressor can adapt to rapid changes in server temperature, reduce frequent opening and closing of the compressor, and also improve system reliability

●Advanced EVO controller, controlling air volume and cooling output as needed, combined with EC fan and DC variable frequency EC compressor to achieve the best effect and minimum

●Energy consumption; Multiple control algorithms can be used to calculate the highest and average temperatures, which can ensure effective cooling and effectively reduce the total temperature

●Physical energy consumption

??

i-Row air-cooled condenser

●Stepless speed regulation owl type fan control

●Extremely low maintenance requirements, suitable for various climatic conditions

inter train cooling

i-Row the model description of the series variable frequency precision inter train cooling between is shown in the table below

?

Indoor unit model:

?

sequence number

1


2

3

4

5

code

IRW

-

LA

025

F

RH

?

The unit model description is as follows:?

Sequence number

code Interpretation

optional

1

brand or series name


2

frequency conversion inter column


3

cooling capacity

12.5kW、25kW、40kW、50kW、60kW

4

air supply mode

F:send before and then return

5

auxiliary heating humidification ? function

NH:humidification

RH:constant temperature and humidity,with auxiliary heat humidification

RN:auxiliary heat

Noon:single cooling, no auxiliary heating ? and no humidification

?

?

Outdoor unit model:?

Sequence?

number

1


2

3

4

5

6

Code

IRW

-

CY

0

X

X

X

?

Note: i-Row-LA series frequency conversion column cooling is composed of indoor unit, controller and outdoor unit.

Parameters of ? air-cooled indoor unit between columns ? Model IRW-LA

12

25

40

50

60

Function

single cooling

single cooling+

constant temperature

single cooling

single cooling+

constant temperature

single cooling

single cooling+

constant temperature

single cooling

single cooling+

constant temperature

single cooling

single cooling+

constant temperature

electric ? heating

constant ? humidity

electric ? heating

constant ? humidity

electric ? heating

constant ? humidity

electric ? heating

constant ? humidity

electric ? heating

constant ? humidity

Air supply mode

F/S

F/S

F

F

F

Input power supply ? form

380Vac/3ph/50Hz

380Vac/3Ph/50Hz

380Vac/3ph/50Hz

380Vac/3Ph/50Hz

380Vac/3Ph/50Hz

Cooling capacity (kw)

12.5

12.5

12.5

25

25

25

40

40

40

50

50

50

60

60

60

Apparent cooling?

capacity?(kw)

12.5

12.5

12.5

25

25

25

40

40

40

50

50

50

60

60

60

Heating ? capacity?(kw)

2

2

3

3

6

6

6

6

6

6

Amount of?

humidification (kg)

1

1.5

3

3

3

Form of compressor

variable frequency compressor

variable frequency compressor

variable frequency compressor

variable frequency compressor

variable frequency compressor

Form of refrigerant

R410A

R410A

R410A

R410A

R410A

Fan form

Dc EC ? centrifugal fan

Dc EC ? centrifugal fan

Dc EC ? centrifugal fan

Dc EC ? centrifugal fan

Dc EC ? centrifugal fan

Air volume ? m3/h

3200

3200

3200

5000

5000

5000

8800

8800

8800

11000

11000

11000

12500

12500

12500

External residual pressure Pa

The standard residual ? pressure is 20Pa, 0-400 Pa ? adjustable

Electric heating form

PTC electric heater

PTC electric heater

PTC electric heater

PTC electric heater

PTC electric heater

Electric heating kw

-

2

2

-

3

3

-

6

6

-

6

6

-

6

6

Form of humidification

wet film humidifier

wet film humidifier

wet film humidifier

wet film humidifier

wet film humidifier

Maximum amount ? of?

humidification kg/h

-

-

1.5

-

-

1.5

-

-

3

-

-

3

-

-

3

Form of throttling

electronic expansion valve

electronic expansion valve

electronic expansion valve

electronic expansion valve

electronic expansion valve

Air filter

G4 plate ? filter

G4 plate ? filter

G4 plate ? filter

G4 plate ? filter

G4 plate ? filter

Humidifier inlet pipe

G1/2

G1/2

G1/2

G1/2

G1/2

In the condensate ? drain (mm)

19

19

19

19

19

In the refrigerant ? pipe?(mm)

15.88

19.05

19.05

22

22

Refrigerant liquid ? pipe?(mm)

9.52

12.7

15.88

19.05

19.05

maximum operating ? current (A)

12

23

23

26

44

44

31

51

51

39

57

57

40

60

60

power cable ? specification (mm3)

5x2.5

5x4

5x4

5x4

5x6

5x6

5x4

5x10

5x10

5x6

5x10

5x10

5x6

5x10

5x10

Indoor machine ? coagulation parameters


Size:width*depth*height (mm)

30ox1200x2000

300x1200x2000

600x1200x2000

60ox1200x2000

600x1200x2000

30Ox140Ox2000

GW (kg)

190

230

285

310

330

Outdoor unit?

model

Standard?

type

CY0191-A1S

CY0451-A1S

CY0742-A1S

CY0893-A1S

CY0893-A1S

Number of?

matches

pc

1

1

1

1

1


① F: rear return air and front air supply, S: side return air and side air supply;

② The standard operating conditions are: indoor dry bulb temperature 37°C, relative humidity 24°C, outdoor dry bulb temperature 35°C;

③ The above table is only part of the parameters, the specific configuration is subject to the actual purchase nameplate, if you need more information about parameters, please contact our company.

Customized services

According to the situation, can customize a variety of air supply.

Optional: port condensate water strong drainage port support up to take over mode port SNMP and TCP/IP interface port dual power input

Note: In addition to the above functions, please contact our company for custom requirements.

?

Parameters of inter column air-cooled outdoor unit?

Model IRW-CY

191

451

742

893

893

Input power

220Vac/1Ph/5OHz

220Vac/1Ph/5OHz

220Vac/1Ph/5OHz

220Vac/1Ph/5OHz

220Vac/1Ph/5OHz

Installation method

tower

horizontal

horizontal

horizontal

horizontal

Form of condensing fan

single phase asynchronous motor+axial flow ? fan blade

Ac axial flow fan

Ac axial flow fan

Ac axial flow fan

Ac axial flow fan

Max current (A)

1.7

3.5

7

10.5

10.5

Speed Control

stepless speed regulation

stepless speed regulation

stepless speed regulation

stepless speed regulation

stepless speed regulation

Power cable specifications (mm)

3x1.5

3x1.5

3x1.5

3x1.5

3x1.5

Outdoor unit structural parameters

Size: W×D×H?(mm)

930x390x1270

1225x1076x960

2075x1076x960

2775x1076x960

2775x1076x960

WG (kg)

65

76

138

169

169

①??Nominal operating conditions for heat exchange: inlet temperature 35 ℃, condensation temperature 50 ℃.

?

?